HOME > Á¦Ç°¼Ò°³ - °èÃø±â > dz¼Ó/dz·®°è - °í¿Â¿ë dz¼Ó°è(6162)

 

 

 

 

 

 Middle and High Temperature Anemomaster

 Probe Model 0203 (Middle temp. Up to 392¨¬F

 

 (200¨¬C))   Model 0204 (High temp. Up to 932¨¬F

 

 500¨¬C))

 

 

 

 

 

 

 

 

 

 

 

 

 Á¦ Ç° °³ ¿ä

 Up to 500¡É for high temperature measurement and 200¡É for middle temperature

 

 measurement of  wind temperature together with the measurement of wind speed by 50m/s.

 This is a thermal anemometer whitch can measure both high and middle temperature by

 

 simply changing a probe and a probe circuit board.

 The instrument that measures velocity is operated by a constant temperature method with

 

 feed-back circuit in velocity measurement and uses a bridge detecting circuit.

 Á¦ Ç° »ç ¾ç

Model 6162

 Middle Temperature Type

(6162 + 0203)

High Temperature Type

(6162 + 0204)

Measuring Function

 Measurement of air velocity and temperature

  Measuring

Range

Air velocity

 0¡­50m/s

Air temperature

0¡­200¡É

0¡­500¡É

Accuracy

 Air velocity

¡¾3% F.S.

Air temperature

¡¾(1%rdg + 1¡É)

 Resolution

Air velocity

0.01m/s : 0¡­4.99m/s, 5¡­10m/s  /  0.1m/s : 10¡­50m/s

Air temperature

0.2¡É : 0¡­99.9¡É  /  1¡É : 100¡­500¡É

Response

Air velocity

Approx. 4sec (90% at air velocity 5m/s)

Air temperature

Approx. 5sec (90% at air velocity 5m/s)

Heat-resisting of Cable

 Teflon coating (probe side) ........ 200¡É

Vinyl code (extension cable) ...... 80¡É

Display

 Digital (simultaneous display of air velocity and temperature)

Input/Output Terminal

 Remote terminal ... START/STOP key

 Analog output terminal ... Output voltage 0¡­1V, accuracy 0.5% F.S.

                          Output impedance 47§Ù

                          Simultaneous output of air velocity temperature

 Digital output terminal ..... RS-232C (serial interface)

Memory

 Max. 999 data (only for the measurement in 1-page)

Ambient Temperature

 5¡­40¡É

Power Supply

 Dry battery drive ..... U2 type (1.5V x 6pcs)

 Alkaline battery, Mn battery

 AC adaptor ..... 12.5V, 450mA (AC 100V¡¾10%, 50/60 Hz)

Dimension

 220(W) x 150(H) x 85(D) mm

Probe

¨ª11 x 208mm

¨ª11 x 1,000mm

Teflon coating 1.5m

Teflon coating 2.3m

Vinyl code 5m

Vinyl code 10m 

Weight

 Main body ..... Approx. 1.8§¸

 Probe ..... Model 0203 : Approx. 200g, Model 0204 : Approx. 500g

Components

 Main Unit(1), AC Adaptor(1), Analog Output Cord(1), Alkaline

 Battery(6), Shoulder Belt(1),  Middle Temperatur or High

 Temperature Probe Set(1), Operation Manual(1)