HOME > Á¦Ç°¼Ò°³ - ¼¾¼­·ù > ¾Ð·Â¼¾¼­ - Àý´ë¾Ð/´ë±â¾Ð ¼¾¼­(270)

 

 

 

 Weather Data Systems

 Laser Interferometers

 Altimeter Setting Indicators

 Transfer Pressure Standard

 Engine Test Cells

 

 

 

 

 

 

 

 

 

 

 

 

 270

Full Scale Pressure Output

5.0 VDC

Zero Pressure Output

0 VDC

Accuracy(RSS Method)

±0.05% Full Scale

Type of Pressure

Absolute / Gage / Barometric

Pressure Ranges

0 to 10, 20, 50, 100 psig / 0 to 5, 10, 20, 50, 100 psig

600 to 1100 hPa/mb / 800 to 1100 hPa/mb

Thermal Effects

Compensated Range °F (°C) : 30 to 120 (-1 to 49)

%FS/100°F(100°C)max.zero : ±0.2 (±0.36) hPa/mb

%FS/100°F(100°C)max.span : ±0.2 (±0.36) hPa/mb

%FS/100°F(100°C)max.zero : ±0.1 (±0.18) other ranges

%FS/100°F(100°C)max.span : ±0.1 (±0.18) other ranges

Media

Non-condensing air or gas compatible with aluminum, alumina

ceramics, gold, fluorocarbon elastomer sealant and Buna-N O-Ring